Gases Measured |
 |
Oxygen (O2)
|
 |
Method of Detection |
 |
Electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition)
|
 |
Ranges Available |
 |
0-5 to 0-25% O2
|
 |
Resolution |
 |
0.1% on % ranges, 1 PPM on PPM ranges
|
 |
Accuracy & Repeatability |
 |
± 1-2% of full scale
|
 |
Drift |
 |
Less than 2% of full scale per month
|
 |
Response Time (T-90) |
 |
20-30 seconds to 90% of step change
|
 |
Ambient Temperature Range |
 |
32 to 122°F (0 to 50°C) @ 5-95% RH non-condensing. Lower temperatures (-5°F, -20°C) with Cold Weather Package. Sample dew point should be at least 9°F (5°C) below lowest sample temperature.
|
 |
Linearity |
 |
±1% of full scale
|
 |
Size & Weight |
 |
Dimensions and weight will vary with configurations selected
|
 |
Power |
 |
115 VAC, 60 Hz 220 VAC, 50 Hz
|
 |
Alarms |
 |
High or low alarm contacts available for all gases and low flow
|
 |
Code Numbers for Gases Measured |
 |
O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition)
|
 |
Sampling System |
 |
Std SS probe with unheated pre-filter (Std. probe 3/8" O.D. x 18") (9.5 x 460 mm)
|
 |
Display Type |
 |
D1 - LED display (s) - Manual potentiometer calibration D2 - LED display (s) - Manual push-button calibration D3 - Microprocessor controller with single graphic display. Allows auto sequencing, RS-485 output, 'CAL NOW' and one-step D4 - Same as D3 but with full auto-calibration
|
 |
Output Options |
 |
OP1 - 4-20 mA non-isolated OP2 - 4-20 mA isolated OP3 - 0-5 V OP4 - 0-10 V OP5 - RS-485 OP6 - Modbus
|
 |
Analyzer Type |
 |
Flue Gas Analyzer
|
 |
Industry Type |
 |
Flue Gas or Emissions
|
 |
| |
|
Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (NO or NO + NO2) or combustibles from combustion processes.
| |
|
- Best value continuous flue gas analyzer with modular sample conditioning
- Oxygen detected by either long life electrochemical sensor, high accuracy paramagnetic sensor or zirconia sensor, depending on desired accuracy and sample composition
- Fast response time and bright digital readout
- Microprocessor based with push button calibration
- Easy to maintain modular layout
- Sample preparation includes moisture removal.
| |
|
- Hi/Low gas, low flow, and diagnostic alarms available
- Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
- Cabinet purge system available for use in hazardous areas
- One-step 'cal-now' button with touch screen LCD display
- Full automatic calibration with touch screen LCD display and low flow switch
- Cold weather package for operation to -5°F (-20°C)
- Cabinet coolers can be fitted to most models
- Sensors mounted in heated box for reduced drift
- High temperature filters and probes
Optional sample conditioning includes:
- Continuous water pre wash system for acidic fuel gases present but not to be analyzed (Model 7300)
- Nafion-Tube™ based sample dryer for high accuracy analysis of acidic samples, where NO2 or SO2 are to be measured (Model 7250)
- Heated stack filter for removal of dust from high dust load (> µ) samples (Model 7240)
- Calibration gas injected at heated stack filter to minimize discrepancies due to absorption of soluble gases.
- Multiple sample point sequencer which allows multiple samples to be selected and analyzed (Model 402AS)
| |
|
|
|
|