名稱 |
產品展示 |
說明 |
備註 |
7200-2-3-4連續煙氣分析儀 |
 |
7200-2-3-4連續煙氣分析儀 - 7200系列 The Nova Model 7200-2-3-4 flue gas analyzer is specifically designed for use on flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-2-3-4 analyzer features an electrochemical sensor or NDIR infrared detector for detecting PPM or % levels of CO, an NDIR infrared detector for detecting % levels of CO2 and an electrochemical sensor for detecting PPM levels of NOx (as NO). Digital readouts and optional outputs are provided for each gas. The 7200-2-3-4 analyzer is multi-sample point capable (consult Nova). |
|
7200-2-3連續煙氣分析儀 |
 |
7200-2-3連續煙氣分析儀 - 7200系列 The Nova Model 7200-2-3 flue gas analyzer is specifically designed for use on gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-2-3 analyzer features an electrochemical sensor or NDIR infrared detector for detecting PPM or % levels of CO and an NDIR infrared detector for detecting % levels of CO2. Digital readouts and optional outputs are provided for each gas. The 7200-2-3 analyzer is multi-sample point capable (consult Nova). |
|
7200-1-2-4連續煙氣分析儀 |
 |
7200-1-2-4連續煙氣分析儀 - 7200系列 The Nova Model 7200-1-2-4 flue gas analyzer is specifically designed for use on flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-1-2-4 analyzer features an electrochemical sensor, paramagnetic sensor or zirconia sensor for detecting % levels of O2, an electrochemical sensor or NDIR infrared detector for detecting PPM or % levels of CO and an electrochemical sensor for detecting PPM levels of NOx (as NO). Digital readouts and optional outputs are provided for each gas. The 7200-1-2-4 analyzer is multi-sample point capable (consult Nova). |
|
7200-1-2-3連續煙氣分析儀 |
 |
7200-1-2-3連續煙氣分析儀 - 7200系列 The Nova Model 7200-1-2-3 flue gas analyzer is specifically designed for use on flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-1-2-3 analyzer features an electrochemical sensor, paramagnetic sensor or zirconia sensor for detecting % levels of O2, an electrochemical sensor or NDIR infrared detector for detecting PPM or % levels of CO, and an NDIR infrared detector for detecting % levels of CO2. Digital readouts and optional outputs are provided for each gas. The 7200-1-2-3 analyzer is multi-sample point capable (consult Nova). |
|
7200-1-4連續煙氣分析儀 |
 |
7200-1-4連續煙氣分析儀 - 7200系列 The Nova Model 7200-1-4 flue gas analyzer is specifically designed for use on the flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-1-4 analyzer features an electrochemical sensor, paramagnetic sensor or zirconia sensor for detecting % levels of O2 and an electrochemical sensor for detecting PPM levels of NOx (as NO), as well as digital readouts and outputs for each gas. The 7200-1-4 analyzer is multi-sample point capable (consult Nova). |
|
7200-1-3連續煙氣分析儀 |
 |
7200-1-3連續煙氣分析儀 - 7200系列 The Nova Model 7200-1-3 flue gas analyzer is specifically designed for use on flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector. The 7200-1-3 analyzer features an electrochemical sensor, paramagnetic sensor or zirconia sensor for detecting % levels of O2, an NDIR infrared detector for detecting % levels of CO2 as well as digital readouts and outputs for each gas. The 7200-1-3 analyzer is multi-sample point capable (consult Nova). |
|
|
|