Method of Detection | 
  | 
Microprocessor based infrared detector for CO2
  |  
  |  
Ranges Available | 
  | 
0-20% CO2
  |  
  |  
Resolution | 
  | 
0.1% CO2
  |  
  |  
Accuracy & Repeatability | 
  | 
Within ±2% full scale
  |  
  |  
Drift | 
  | 
Within 1% full scale per 8 hours of continuous operation
  |  
  |  
Response Time (T-90) | 
  | 
30 - 40 seconds
  |  
  |  
Ambient Temperature Range | 
  | 
0 to 40 ºC 32 to 105 ºF
  |  
  |  
 
Linearity | 
  | 
Better than 1.0% of full scale
  |  
  |  
Size & Weight | 
  | 
11 1/2" L x 8" H x 7 1/4" D @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)
  |  
  |  
Power | 
  | 
AC/DC Operation, 115 VAC, 60 Hz for recharging
  |  
  |  
Output Options | 
  | 
0-1 VDC 4-20 mA
  |  
  |  
Alarms | 
  | 
High or low CO2 alarm with LED (optional)
  |  
  |  
Hazardous Area Rating Options | 
  | 
General Purpose, Non-Hazardous
  |  
  |   
  |    | 
 
 | 
Analysis of carbon dioxide (CO2). For checking combustion efficiency, and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
 
 
   |    | 
 
 | 
- Rugged design that is easy to operate
 
- Fast warm-up and response
 
- Solid state infrared detector
 
- Digital readout meter with backlight
 
- Modular layout that is easy to maintain
 
- Rechargeable battery operation
 
- Built in sample pump, filter and flowmeter
 
- Active condensate removal
 
- Weatherproof (WP) cabinet with clear Lexan cover
 
- Stainless steel probe with sample hose
  
 
 
  |    | 
 
 | 
- Recorder outputs of 0-1 V or 4-20 mA (can be isolated)
 
- Stack temperature readout (302T)
 
- Special sampling probes
 
- Sample pre-cooler
 
- Suitcase (K) style cabinet available
 
- AC power only operation
 
- CO2 alarms with LED
 
- Data logger
  
 
 
  |    | 
 
 | 
- Air for zero (except low range models which have a CO2 scrubber for zeroing).
 
- Analyzed CO2 cal gas for span.
   |    |