Method of Detection |
 |
Temperature compensated thermal conductivity (T/C) cell
|
 |
Ranges Available |
 |
0-100% SF6 in air or in N2
|
 |
Resolution |
 |
0.1% of He
|
 |
Accuracy & Repeatability |
 |
±2% of full scale
|
 |
Drift |
 |
±1% of full scale per day (after calibration)
|
 |
Response Time (T-90) |
 |
10-15 seconds to 90% step change - not including sample transport time
|
 |
Ambient Temperature Range |
 |
12 to 50 ºC 55 to 120 ºF
|
 |
Linearity |
 |
±2% of F.S. on SF6 in Air
|
 |
Size & Weight |
 |
11 1/2" L x 8" W x 7 1/4" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)
|
 |
Power |
 |
AC/DC Operation. 115 VAC, 60 Hz for recharging (220 VAC, 50 Hz available)
|
 |
Output Options |
 |
4-20 mA or 0-1 VDC
|
 |
Alarms |
 |
High or low SF6 alarm (optional)
|
 |
Hazardous Area Rating Options |
 |
General Purpose, Non-Hazardous
|
 |