Specifications

Method of Detection

O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor

Ranges Available

0-100 PPM NO
0-100% RH
0-20 PPM H2S
0-20 PPM NH3
0-20.0 PPM CL2
0-20.0 PPM NO2
0-200 PPM CO
0-200 PPM H2
0-25.0% O2
0-50°C Temp.
0-50.0 PPM SO2
0-5000 PPM CO2

Resolution

0.1% on % gas, 1 PPM on PPM gas

Accuracy & Repeatability

±2% of full scale

Drift

2% per month

Response Time (T-90)

Varies with individual sensor but generally under 2 minutes for full reading

Ambient Temperature Range

4 to 40 ºC
40 to 105 ºF

Linearity

±2% of full scale or 1 PPM, whichever is greater

Size & Weight

Dimensions and weight will vary based on the number of gases and sample conditioning system

Power

115 VAC, 60 Hz for recharging
220 VAC, 50 Hz

Output Options

4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, ethernet

Alarms

One low O2 alarm and one high alarm for all other gases. Separate relay contacts for each gas with 5A rating. Separate indicator lights. Common 'Sonalert' audible alarm with reset button. Field-adjustable set points.

Gases Measured

0) NH3 - 0-20 PPM
1) O2 - 0-25.0%
2) CO - 0-200 PPM
3) CO2 - 0-5000 PPM
4) LEL Combustibles (not avail. for 5287 Series)
5) H2S - 0-20 PPM
6) SO2 - 0-50 PPM
7) NO - 0-100 PPM
8) NO2 - 0-20 PPM
9) CL2 - 0-20 PPM


Applications
    For simultaneous analysis and alarm of up to six of any combination of O2 deficiency, CO2, SO2, NO, NO2, H2, CO, CL2, NH3, H2S, % RH, and temperature of ambient air.



Features
  • All gas detectors contained in one NEMA 12 wall mounted enclosure
  • Microprocessor controlled sensors
  • Separate sensor for each gas
  • Bright digital readout for each gas
  • Built in sampling pump
  • Easy to maintain modular layout
  • Single alarm points for each gas with individual alarm lights and common 'sonalert' audible alarm
  • Audible alarm reset button provided
  • Alarm contact for each gas
  • Recorder output of 4-20mA or voltage for all gases




Options
  • Isolated analog RS-232, RS-485, MODBUS, or ethernet outputs available
  • Strobe light
  • RS-485 output
  • Automatic calibration with touch screen display
  • Low sample flow alarm
  • Multiple alarm points for measured gases
  • Multipoint sampling using Nova 402AS




Calibration
  • Isolated analog RS-232, RS-485, MODBUS, or ethernet outputs available
  • Strobe light
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号