Specifications

Method of Detection

O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor, combustibles by catalytic sensor

Ranges Available

0-100 PPM NO
0-100% RH
0-20 PPM H2S
0-20 PPM NH3
0-20.0 PPM CL2
0-20.0 PPM NO2
0-200 PPM CO
0-200 PPM H2
0-25.0% O2
0-50°C Temp.
0-50.0 PPM SO2
0-5000 PPM CO2

Resolution

0.1% on % gas, 1 PPM on PPM gas

Accuracy & Repeatability

±2% of full scale

Drift

Less than 1% of full scale or 1 PPM per 8 hours, whichever is greater, with constant ambient temperature

Response Time (T-90)

Varies with individual sensor but generally under 2 minutes for full reading

Ambient Temperature Range

4 to 49 ºC
40 to 120 ºF

Linearity

±2% of full scale or 1 PPM, whichever is greater

Size & Weight

15" W x 7" H x 12" D @ 14 lbs. (375 x 175 x 305 mm @ 6.4 kg)

Power

115 VAC, 60 Hz for recharging
220 VAC, 50 Hz

Output Options

0-1 VDC
4-20 mA

Alarms

Audible and visual alarms are optionally available as well as low battery and low flow

Gases Measured

0) NH3 - 0-20 PPM
1) O2 - 0-25.0%
2) CO - 0-200 PPM
3) CO2 - 0-5000 PPM
4) LEL Combustibles (not avail. for 5287 Series)
5) H2S - 0-20 PPM
6) SO2 - 0-50 PPM
7) NO - 0-100 PPM
8) NO2 - 0-20 PPM
9) CL2 - 0-20 PPM


Applications
    For ambient air or confined space monitoring for up to any six choices of O2, CO2 SO2, NO, NO2, H2, CO, CL2, NH3, H2S, LEL combustibles, temperature, and % RH.



Features
  • Rugged design that is easy to operate and maintain
  • Fast warm-up and response
  • Separate electrochemical sensor for O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S
  • Sensitive infrared detector for CO2
  • Catalytic sensor for combustibles
  • Capacitive ceramic sensor for % RH
  • Digital readout with backlighting for each gas
  • Built in sampling pump, flow meter, filter and 12 ft. sampling hose
  • Rechargeable battery
  • Rugged suitcase (K) style case




Options
  • Recorder outputs of 0-1 V or 4-20 mA
  • Audible and visual alarms
  • Built in printer
  • Detachable/portable data logger




Calibration
  • Nitrogen (N2) for zero
  • Analyzed gas cylinders for span




Unique Applications
    Warm up time is approximately two minutes however NO and NH3 may take up to 2 hours for full stability. The operating humidity range for this series of analyzers is 0-90% RH non-condensing. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.



Models & Configuration Guidelines
    Standard system comes with 'K' series suitcase-style enclosure, built-in sampling pump, flow meter, pre-filter, liquid block, 12 ft (3.6 m) sample hose, rechargeable battery, and recharger.

    Arrange Gas numbers in the following order (up to six gases) :

    1) O2 - 0-25.0%
    2) CO - 0-200 PPM
    3) CO2 - 0-5000 PPM
    4) LEL - Combustibles (not avail. for 5287 Series)
    5) H2S - 0-20 PPM
    6) SO2 - 0-50 PPM
    7) NO - 0-100 PPM
    8) NO2 - 0-20 PPM
    9) CL2 - 0-20 PPM
    0) NH3 - 0-20 PPM
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号