Language:       
High-quality products
&
professional services
 
  About us
  Products
  News center
  Support & serivces
  Solution & Application
  Service Network
  Contact us
  link



Specifications

Method of Detection

Customer replaceable electrochemical oxygen and CO sensors
Solid state infra-red detector for CO2

Ranges Available

0-1800°F (0-1000°C) stack temperature
0-20.0% CO2
0-2000 PPM and 0-4.00% CO - Switch selectable
0-25.0% Oxygen

Resolution

0.1% O2, 1 PPM on CO and CO2

Accuracy & Repeatability

2% of full scale for O2 and CO2; ±10 PPM CO

Drift

<2% full scale per 8 hours of continuous operation

Response Time (T-90)

10-15 seconds for O2; 20-30 seconds for CO and CO2

Ambient Temperature Range

0 to 40 ºC
32 to 105 ºF

Linearity

±1.0% of full scale for each gas measured

Size & Weight

16" L x 4 1/2" H x 8" D @ 13 lbs (40.6 x 20.3 x 10.8 cm @ 5.6 kg)

Power

AC/DC Operation, 115 VAC 60 Hz for recharging (Other voltages available.)

Output Options

0-1 VDC
4-20 mA

Hazardous Area Rating Options

General Purpose, Non-Hazardous


Applications
    Analysis of oxygen (O2), carbon monoxide (CO), and carbon dioxide (CO2). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.




Features
  • Rugged design that is easy to operate
  • Fast warm up and response
  • CO2 actually measured by infrared detector, not calculated
  • Dual CO range : 0-2000 ppm & 0-4.00%
  • Rapid reading recovery after CO 'overdose'
  • Digital readout meters with backlight
  • Modular design that is easy to maintain
  • Rechargeable battery operation
  • Built in sample pump, filter and flow meter
  • Active condensate removal
  • Weatherproof (WP) cabinet with clear Lexan cover
  • Stainless steel probe with sample hose




Options
  • Outputs of 0-1 V or 4-20 mA (can be isolated)
  • Special sampling probes
  • Suitcase (K) style cabinet available
  • AC power only operation
  • Gas alarms with LED
  • Detachable/portable data logger




Calibration
  • Air for O2 span and CO/CO2 zero
  • Analyzed gas mixtures of CO2 and CO in nitrogen for span
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号