Material Level Control
 
Flow Instrumenst
 
Gas/Liquid Analytical
 
Electrical Products
 
Other Products
 
Process Weighing
 

Oxygen Analyzer

Name Product show Description Remarks
415N7MC Process Analyzer for Trace Oxygen
415N7MC Process Analyzer for Trace Oxygen,Electrochemical Sensor,Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration,Class1 Div1 Group B,C,D
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
415RM Process Analyzer for Trace Oxygen
415RM Process Analyzer for Trace Oxygen ,Electrochemical Sensor,19" (483mm) Rack Mounted, on Sliding Rails
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
415PM Process Analyzer for Trace Oxygen
415PM Process Analyzer for Trace Oxygen,Electrochemical Sensor,Panel Mounted, Slides Open for Easy Access
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
415N12 Process Analyzer forTrace Oxygen
415N12 Process Analyzer for Trace Oxygen Electrochemical Sensor, Wall Mounted NEMA12 (IP52) Enclosure Rating
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
415N4X Process Analyzer forTrace Oxygen
415N4X Process Analyzer forTrace Oxygen,Electrochemical Sensor,Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
415N4 Process Analyzer for Trace Oxygen
415N4 Process Analyzer for Trace Oxygen,Electrochemical Sensor,Wall Mounted NEMA4 (IP65) Enclosure Rating
The Nova 415 Series Trace O2 analyzers have been designed for the detection of trace levels of O2 in a non-corrosive gas stream. In operation, the O2 content in the sample gas is detected by a 'fuel cell' type electrochemical sensor. This sensor produces a small current output directly proportional to the O2 in the sample. This small output is compensated for temperature, amplified, and then displayed in PPM O2 on a digital meter. The signal is also sent to recorder terminals as a voltage or current output. As the sensor ages, the sealed internal electrolyte will be consumed and will require eventual replacement. The sensor normally lasts about 12 to 18 months and is a nominal-cost customer-replaceable part.
 
First Previous Next Last
 Go
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号