975A Continuous Analyzer
975A Continuous Analyzer,Syn-Gas Atmospheres - O2, CO, CO2, CH4 and H2
The Nova 970 Series Syn-Gas Analyzer System has been designed with the flexibility and robustness required in the experimental and developmental environments that characterize syn gas applications.

The Nova 970 Series utilizes high-stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition. A non-depleting paramagnetic sensor is used for O2 analysis. All sensors/detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Auto calibration functionality allows easy calibration without user intervention. The included Serial Output Package allows connection of analyzer to personal computers via a choice of USB/RS-232/RS-485. Data recording software is also included.

 
42387 Process Analyzer
42387 Process Analyzer,Hydrogen with Carbon Dioxide Compensation, H2 with CO2, CO, & CH4 compensation.
The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal conductivity cell (T/C).
To correct the H2 reading for the presence of CO2, the 4230 has a separate infra red CO2 detector. Its purpose is to provide the exact amount of corrective signal for the Hydrogen reading, regardless of the furnace or generator conditions. This is a most desirable feature, especially when trying to obtain very accurate hydrogen readings.
Some manufacturers attempt to compensate the H2 reading for CO2 by advising the customer to obtain a calibration gas that also contains CO2. This approach is only effective at that particular H2/CO2 ratio. As soon as the process gas H2 level deviates from the calibration H2 level, the readings become more inaccurate. Continuous CO2 compensation is the only effective way to deal with this problem.
 
42381 Process Analyzer
42381 Process Analyzer,Hydrogen with Carbon Dioxide Compensation, H2 with CO & CO2 compensation
The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal conductivity cell (T/C).
To correct the H2 reading for the presence of CO2, the 4230 has a separate infra red CO2 detector. Its purpose is to provide the exact amount of corrective signal for the Hydrogen reading, regardless of the furnace or generator conditions. This is a most desirable feature, especially when trying to obtain very accurate hydrogen readings.
Some manufacturers attempt to compensate the H2 reading for CO2 by advising the customer to obtain a calibration gas that also contains CO2. This approach is only effective at that particular H2/CO2 ratio. As soon as the process gas H2 level deviates from the calibration H2 level, the readings become more inaccurate. Continuous CO2 compensation is the only effective way to deal with this problem.
 
4381 Process Analyzer
4381 Process Analyzer,Hydrogen with Carbon Dioxide Compensation, H2 with CO compensation
The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal conductivity cell (T/C).
To correct the H2 reading for the presence of CO2, the 4230 has a separate infra red CO2 detector. Its purpose is to provide the exact amount of corrective signal for the Hydrogen reading, regardless of the furnace or generator conditions. This is a most desirable feature, especially when trying to obtain very accurate hydrogen readings.
Some manufacturers attempt to compensate the H2 reading for CO2 by advising the customer to obtain a calibration gas that also contains CO2. This approach is only effective at that particular H2/CO2 ratio. As soon as the process gas H2 level deviates from the calibration H2 level, the readings become more inaccurate. Continuous CO2 compensation is the only effective way to deal with this problem.
 
4370 Process Analyzer
4370 Process Analyzer,Hydrogen with Carbon Dioxide Compensation, H2 with CH4 Compensation
The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal conductivity cell (T/C).
To correct the H2 reading for the presence of CO2, the 4230 has a separate infra red CO2 detector. Its purpose is to provide the exact amount of corrective signal for the Hydrogen reading, regardless of the furnace or generator conditions. This is a most desirable feature, especially when trying to obtain very accurate hydrogen readings.
Some manufacturers attempt to compensate the H2 reading for CO2 by advising the customer to obtain a calibration gas that also contains CO2. This approach is only effective at that particular H2/CO2 ratio. As soon as the process gas H2 level deviates from the calibration H2 level, the readings become more inaccurate. Continuous CO2 compensation is the only effective way to deal with this problem.
 
4230PMN7 Process Analyzer
4230PMN7 Process Analyzer,Hydrogen with Carbon Dioxide Compensation, Wall Mounted,NEMA7 Sensor Housing with Panel Mounted Control Cabinet (Two Separate Enclosures)
The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal conductivity cell (T/C).
To correct the H2 reading for the presence of CO2, the 4230 has a separate infra red CO2 detector. Its purpose is to provide the exact amount of corrective signal for the Hydrogen reading, regardless of the furnace or generator conditions. This is a most desirable feature, especially when trying to obtain very accurate hydrogen readings.
Some manufacturers attempt to compensate the H2 reading for CO2 by advising the customer to obtain a calibration gas that also contains CO2. This approach is only effective at that particular H2/CO2 ratio. As soon as the process gas H2 level deviates from the calibration H2 level, the readings become more inaccurate. Continuous CO2 compensation is the only effective way to deal with this problem.
 
First Previous Next Last
 Go
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号