912C Continuous Analyzer |
 |
912C Continuous Analyzer,Landfill Site and Biogas Recovery & Processing - Automatic Calibration - O2 and CH4 The Nova 910 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The 910 Series comes complete with pre-filter, sample pump, flow meter, continuous moisture removal system, long-life O2 sensor, infrared CO2/CH4 detector, low flow sensor, alarm relay contacts, and 4-20mA outputs for each gas measured. The sensors/detectors are mounted in an internal dedicated enclosure which is heated and temperature controlled to reduce drift due to ambient temperature swings. The internal sensor enclusure is removable to allow quick field change of the sensors. The infra-red detector can be cleaned in the field if necessary by the on-site technician. Environmental management packages are available to allow operation of th analyzer outdoors in temperatures from -30 °C (-22 °F) to 70 °C (158 °F). On the C models with Autocalibration, all calibration functions are controlled through the display rather than manual potentiometers. The operator only has to input the calibration frequency and leave calibration gas cylinders connected to the analyzer - the rest is automatic. Diagnostics and troubleshooting information are also included in the display interface of the C models. This assists operators to quickly determine the cause of an alarm and get the analyzer back on-line. |
|
912A Continuous Analyzer |
 |
912A Continuous Analyzer,Landfill Site and Biogas Recovery & Processing - Manual Calibration - O2 and CH4 The Nova 910 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The 910 Series comes complete with pre-filter, sample pump, flow meter, continuous moisture removal system, long-life O2 sensor, infrared CO2/CH4 detector, low flow sensor, alarm relay contacts, and 4-20mA outputs for each gas measured. The sensors/detectors are mounted in an internal dedicated enclosure which is heated and temperature controlled to reduce drift due to ambient temperature swings. The internal sensor enclusure is removable to allow quick field change of the sensors. The infra-red detector can be cleaned in the field if necessary by the on-site technician. Environmental management packages are available to allow operation of th analyzer outdoors in temperatures from -30 °C (-22 °F) to 70 °C (158 °F). On the C models with Autocalibration, all calibration functions are controlled through the display rather than manual potentiometers. The operator only has to input the calibration frequency and leave calibration gas cylinders connected to the analyzer - the rest is automatic. Diagnostics and troubleshooting information are also included in the display interface of the C models. This assists operators to quickly determine the cause of an alarm and get the analyzer back on-line. |
|
911A Continuous Analyzer |
 |
911A Continuous Analyzer,Landfill Site and Biogas Recovery & Processing - Manual Calibration - CH4 only The Nova 910 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The 910 Series comes complete with pre-filter, sample pump, flow meter, continuous moisture removal system, long-life O2 sensor, infrared CO2/CH4 detector, low flow sensor, alarm relay contacts, and 4-20mA outputs for each gas measured. The sensors/detectors are mounted in an internal dedicated enclosure which is heated and temperature controlled to reduce drift due to ambient temperature swings. The internal sensor enclusure is removable to allow quick field change of the sensors. The infra-red detector can be cleaned in the field if necessary by the on-site technician. Environmental management packages are available to allow operation of th analyzer outdoors in temperatures from -30 °C (-22 °F) to 70 °C (158 °F). On the C models with Autocalibration, all calibration functions are controlled through the display rather than manual potentiometers. The operator only has to input the calibration frequency and leave calibration gas cylinders connected to the analyzer - the rest is automatic. Diagnostics and troubleshooting information are also included in the display interface of the C models. This assists operators to quickly determine the cause of an alarm and get the analyzer back on-line. |
|
910A Continuous Analyzer |
 |
910A Continuous Analyzer,Landfill Site and Biogas Recovery & Processing - Manual Calibration - O2 only The Nova 910 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The 910 Series comes complete with pre-filter, sample pump, flow meter, continuous moisture removal system, long-life O2 sensor, infrared CO2/CH4 detector, low flow sensor, alarm relay contacts, and 4-20mA outputs for each gas measured. The sensors/detectors are mounted in an internal dedicated enclosure which is heated and temperature controlled to reduce drift due to ambient temperature swings. The internal sensor enclusure is removable to allow quick field change of the sensors. The infra-red detector can be cleaned in the field if necessary by the on-site technician. Environmental management packages are available to allow operation of th analyzer outdoors in temperatures from -30 °C (-22 °F) to 70 °C (158 °F). On the C models with Autocalibration, all calibration functions are controlled through the display rather than manual potentiometers. The operator only has to input the calibration frequency and leave calibration gas cylinders connected to the analyzer - the rest is automatic. Diagnostics and troubleshooting information are also included in the display interface of the C models. This assists operators to quickly determine the cause of an alarm and get the analyzer back on-line. |
|
971F Continuous Analyzer |
 |
971F Continuous Analyzer,Syn-Gas Atmospheres - O2 only The Nova 970 Series Syn-Gas Analyzer System has been designed with the flexibility and robustness required in the experimental and developmental environments that characterize syn-gas applications. The Nova 970 Series utilizes high-stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition. A non-depleting paramagnetic sensor is used for O2 analysis. All sensors/detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Auto calibration functionality allows easy calibration without user intervention. The included Serial Output Package allows connection of analyzer to personal computers via a choice of USB/RS-232/RS-485. Data recording software is also included. |
|
971E Continuous Analyzer |
 |
971E Continuous Analyzer,Syn-Gas Atmospheres - CO2 only The Nova 970 Series Syn-Gas Analyzer System has been designed with the flexibility and robustness required in the experimental and developmental environments that characterize syn-gas applications. The Nova 970 Series utilizes high-stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition. A non-depleting paramagnetic sensor is used for O2 analysis. All sensors/detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Auto calibration functionality allows easy calibration without user intervention. The included Serial Output Package allows connection of analyzer to personal computers via a choice of USB/RS-232/RS-485. Data recording software is also included. |
|
|